Call Us Today: (800) 462-7733
Digital monitoring relay cos phi and current monitoring from 90-690 V AC 0vershoot and undershoot self-supplied 50 to 60 HZ AC noise pulses delay 0.1 to 20 s hysteresis for (i) 0.1 to 2 a 2 change-over contacts with or without fault bufferscrew terminal successor product for 3ug3014
Digital monitoring relay cos phi and current monitoring from 90-690 V AC 0vershoot and undershoot self-supplied 50 to 60 HZ AC noise pulses delay 0.1 to 20 s hysteresis for (i) 0.1 to 2 a 2 change-over contacts with or without fault bufferscrew terminal successor product for 3ug3014

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3UG46411CS20

$383.83 / EA

manufacturer discounts
learn about discounts

  • $344.12 for $1,500.00+
  • $330.89 for $2,500.00+
  • $317.65 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

Digital monitoring relay cos phi and current monitoring from 90-690 V AC 0vershoot and undershoot self-supplied 50 to 60 HZ AC noise pulses delay 0.1 to 20 s hysteresis for (i) 0.1 to 2 a 2 change-over contacts with or without fault bufferscrew terminal successor product for 3ug3014

Digital monitoring relay cos phi and current monitoring from 90-690 V AC 0vershoot and undershoot self-supplied 50 to 60 HZ AC noise pulses delay 0.1 to 20 s hysteresis for (i) 0.1 to 2 a 2 change-over contacts with or without fault bufferscrew terminal successor product for 3ug3014

150

UPC
754554937441
UNSPSC
39122333
Country of Origin
DE
Adaptable response value phase displacement angle / Full-scale value:
0.99 °
Adaptable response value phase displacement angle / initial value:
0.1 °
Adjustable response delay time / when starting / Full-scale value:
99 s
Adjustable response delay time / with lower or upper limit violation / Full-scale value:
20 s
Ambient temperature / during operation / maximum:
60 °C
Ambient temperature / during operation / minimum:
-25 °C
Control supply voltage / at AC / at 60 Hz / Rated value / maximum:
690.0 V
Control supply voltage / at AC / at 60 Hz / Rated value / minimum:
90.0 V
Control supply voltage / rated value / maximum:
690 V
Control supply voltage / rated value / minimum:
90 V
Compare With Similar Items
Digital monitoring relay voltage monitoring, 22.5mm from 0.1 to 60V AC/DC overshoot and undershoot AC/DC 24 to 240V DC and AC 50 to 60 HZ spike delay 0.1 to 20s hysteresis 0.1 to 30v 1 changeover contact w. or w/o error log spring-loaded type

3UG46312AW30

$291.80 /ea

Digital monitoring relay voltage monitoring, 22.5mm from 0.1 to 60V AC/DC overshoot and undershoot AC/DC 24 to 240V DC and AC 50 to 60 HZ spike delay 0.1 to 20s hysteresis 0.1 to 30v 1 changeover contact w. or w/o error log spring-loaded type

Attributed Data Included
Accuracy of digital display +/-1digit Yes
Type of electrical connection spring-loadedterminals Yes
Type of voltage / for monitoring AC/DC Yes
Digital monitoring relay speed monitoring from 0.1 to 2200 rev/min overshoot and undershoot AC/DC 24V DC and AC 50 to 60 HZ startup delay 1 to 900s tripping delayed 0.1 to 99.9s hysteresis 0.1 to 99 rev/min 1 changeover contact w. or w/o error log sc...

3UG4651-1AA30

$473.61 /ea

Digital monitoring relay speed monitoring from 0.1 to 2200 rev/min overshoot and undershoot AC/DC 24V DC and AC 50 to 60 HZ startup delay 1 to 900s tripping delayed 0.1 to 99.9s hysteresis 0.1 to 99 rev/min 1 changeover contact w. or w/o error log screw terminal replacement product f. 3ug3051

Attributed Data Included
Operating range factor control supply voltage rated value / at DC / Full-scale value 1.1 Yes
Operating range factor control supply voltage rated value / at DC / initial value 0.8 Yes
Digital monitoring relay speed monitoring from 0.1 to 2200 rev/min overshoot and undershoot AC/DC 24 to 240V DC and AC 50 to 60 HZ startup delay 1 to 900s tripping delayed 0.1 to 99.9s hysteresis 0.1 to 99 rev/min 1 changeover contact w. or w/o error...

3UG4651-1AW30

$507.28 /ea

Digital monitoring relay speed monitoring from 0.1 to 2200 rev/min overshoot and undershoot AC/DC 24 to 240V DC and AC 50 to 60 HZ startup delay 1 to 900s tripping delayed 0.1 to 99.9s hysteresis 0.1 to 99 rev/min 1 changeover contact w. or w/o error log screw terminal replacement product f. 3ug3051

Attributed Data Included
Operating range factor control supply voltage rated value / at DC / Full-scale value 1.1 Yes
Operating range factor control supply voltage rated value / at DC / initial value 0.8 Yes

ADDED TO CART