ISOLATING TRANSFORMER 61558-2-6, EN61131-2 SAFETY INSTALLATION SCREW EN TERMINALS SCREW CONNECTION /B W(%) 4,2 IP00 TYPE OF PROTECTION CL. I TA/ISOKL 60 GR./SHIELD WNG. II0 /0 F(HZ) 50...60 VECTOR DC) 24 ISEC(A DC) 9 400(415)-230(240)-200 USEC(V UPRI(V) 575(600)-500-460(480)- PN(KW) 0,216 POWER SUPPLY PHASES 3
ISOLATING TRANSFORMER 61558-2-6, EN61131-2 SAFETY INSTALLATION SCREW EN TERMINALS SCREW CONNECTION /B W(%) 4,2 IP00 TYPE OF PROTECTION CL. I TA/ISOKL 60 GR./SHIELD WNG. II0 /0 F(HZ) 50...60 VECTOR DC) 24 ISEC(A DC) 9 400(415)-230(240)-200 USEC(V UPRI(V) 575(600)-500-460(480)- PN(KW) 0,216 POWER SUPPLY PHASES 3

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

4AV3002-2EB00-0A

$3,575.64 / EA

manufacturer discounts
learn about discounts

  • $3,205.75 for $1,500.00+
  • $3,082.45 for $2,500.00+
  • $2,959.15 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

ISOLATING TRANSFORMER 61558-2-6, EN61131-2 SAFETY INSTALLATION SCREW EN TERMINALS SCREW CONNECTION /B W(%) 4,2 IP00 TYPE OF PROTECTION CL. I TA/ISOKL 60 GR./SHIELD WNG. II0 /0 F(HZ) 50...60 VECTOR DC) 24 ISEC(A DC) 9 400(415)-230(240)-200 USEC(V UPRI(V) 575(600)-500-460(480)- PN(KW) 0,216 POWER SUPPLY PHASES 3

ISOLATING TRANSFORMER 61558-2-6, EN61131-2 SAFETY INSTALLATION SCREW EN TERMINALS SCREW CONNECTION /B W(%) 4,2 IP00 TYPE OF PROTECTION CL. I TA/ISOKL 60 GR./SHIELD WNG. II0 /0 F(HZ) 50...60 VECTOR DC) 24 ISEC(A DC) 9 400(415)-230(240)-200 USEC(V UPRI(V) 575(600)-500-460(480)- PN(KW) 0,216 POWER SUPPLY PHASES 3

150

UPC
754554769271
UNSPSC
39121026
Country of Origin
CZ
Ambient temperature / rated value:
60 °C
Certificate of suitability:
CE
Construction form of the iron core:
3UI75/25
Depth:
115 m
Electrical input frequency / maximum:
60 Hz
Electrical input frequency / minimum:
50 Hz
Height:
190 m
Input voltage / _1 / rated value:
575 V
Input voltage / _2 / rated value:
500 V
Input voltage / _3 / rated value:
460 V
Input voltage / _4 / rated value:
400 V
Input voltage / _5 / rated value:
230 V
Input voltage / _6 / rated value:
200 V
Input voltage / maximum:
609.50 V
Input voltage / minimum:
180 V
Operating resource protection class:
I
Output current / _1 / rated value:
9 A
Output current / at DC / at 40 °C / rated value / maximum:
11 A
Output current / at DC / at 60 °C / rated value / maximum:
9 A
Output voltage / _1 / rated value:
24 V
Output voltage / of the measurement signal / at analog output / at DC / maximum:
28.8 V
Output voltage / of the measurement signal / at analog output / at DC / minimum:
20.4 V
Phase number / of the inputs:
3
Product designation:
4AV3002-2EB00-0A
Product function / Insulation monitoring:
No
Product function / Short-circuit and overload proof:
No
Product function / Temperature monitoring:
No
Product function / varistor protective wiring:
Yes
Protection class IP:
IP00
Relative residual ripple / of the output voltage 1 / for main current circuit / maximum:
5 %
Thermal class / acc. to IEC 60085:
B
Type of current / _1 / at output:
DC
Type of current / of the inputs:
AC
Vector group:
Ii0
Width:
164 m
product brand name:
SIDAC
Compare With Similar Items
Machine Tool Rated Molded Industrial Control Transformer, 120x240 PV, 120x240 SV, 250 kVA

PH250PP

$129.20 /ea

Machine Tool Rated Molded Industrial Control Transformer, 120x240 PV, 120x240 SV, 250 kVA

TRANSFORMER SITAS PHASES 1 PN/PN(S6)(KVA) 0,1 /0,31 UPRI(V) 440-400-230 USEC(V)230(2X115) ISEC(A) 0,435-0,870 F(HZ) 50...60 VECTOR GR./SHIELD WNG. IIII0 /0 TA/ISOKL 40 /B IP00 TYPE OF TERMINALS SCREW/TAB CONNECTION INSTALLATION SCREWS/MOUNTING RAILS...

4AM34428MD400FA0

$650.93 /ea

TRANSFORMER SITAS PHASES 1 PN/PN(S6)(KVA) 0,1 /0,31 UPRI(V) 440-400-230 USEC(V)230(2X115) ISEC(A) 0,435-0,870 F(HZ) 50...60 VECTOR GR./SHIELD WNG. IIII0 /0 TA/ISOKL 40 /B IP00 TYPE OF TERMINALS SCREW/TAB CONNECTION INSTALLATION SCREWS/MOUNTING RAILS EN 61558-2-1, -2-2, -2-4 UL/CSA-RECOGNIZED >CONTROL CIRCUIT TRANSFORMER >ISOLATION TRANSFORMER

Attributed Data Included
Mounting type screws/standardrail Yes
Product function / Insulation monitoring No Yes
Product function / Short-circuit and overload proof No Yes
Product function / Temperature monitoring No Yes
Type of electrical connection / at input / for main current circuit screw-typeterminals/tabterminals Yes
Type of electrical connection / at output / for main current circuit screw-typeterminals/tabterminals Yes
TRANSFORMER SITAS PHASES 1 PN/PN(S6)(KVA) 4 /16 UPRI(V) 400+/-5% USEC(V) 110 ISEC(A) 36.4 F(HZ) 50...60 VECTOR GR./SHIELD WNG. II0 /0 TA/ISOKL 55 /H IP00 TYPE OF TERMINALS SCREW CONNECTION INSTALLATION SCREW EN 61558-2-1. -2-2. -2-4 UL/CSA-RECOGNIZED...

4AT30325AJ100FA0

$7,563.19 /ea

TRANSFORMER SITAS PHASES 1 PN/PN(S6)(KVA) 4 /16 UPRI(V) 400+/-5% USEC(V) 110 ISEC(A) 36.4 F(HZ) 50...60 VECTOR GR./SHIELD WNG. II0 /0 TA/ISOKL 55 /H IP00 TYPE OF TERMINALS SCREW CONNECTION INSTALLATION SCREW EN 61558-2-1. -2-2. -2-4 UL/CSA-RECOGNIZED ( ) >CONTROL

Attributed Data Included
Mounting type screws Yes
Product function / Insulation monitoring No Yes
Product function / Short-circuit and overload proof No Yes
Product function / Temperature monitoring No Yes
Type of electrical connection / at input / for main current circuit screw-typeterminals Yes
Type of electrical connection / at output / for main current circuit screw-typeterminals Yes