Call Us Today: (800) 462-7733
This AC hardwired signaling device is designed to meet the needs of the ADA where a 177 candela strobe light is required for deaf & hard of hearing residential and institutional applications.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

SL177

Manufacturer
Kidde Safety

$81.69 / EA

manufacturer discounts
learn about discounts

  • $75.86 for $1,300.00+
  • $72.94 for $2,000.00+
  • $70.02 for $3,000.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

This AC hardwired signaling device is designed to meet the needs of the ADA where a 177 candela strobe light is required for deaf & hard of hearing residential and institutional applications.

This AC hardwired signaling device is designed to meet the needs of the ADA where a 177 candela strobe light is required for deaf & hard of hearing residential and institutional applications.

150

UPC
029054002709
UNSPSC
46191505
Country of Origin
MX
Amperage Rating:
0.05 AMP Standby
Type:
Hearing Impaired Smart Strobe
Voltage Rating:
120 VAC
Amperage Rating:
0.05 AMP Standby
Candle Power:
177 CND
Environmental Conditions:
Humidity: 10 - 90 PCT Relative Humidity (RH)
Flashes Per Minute:
60
Mounting:
4 IN Octagon Box
Standard:
UL1971, ANSI 117.1, CSFM, NFPA 72, NFPA 101 And ICC, ADA Approved
Sub Brand:
First Alert
Type:
Hearing Impaired Smart Strobe
Voltage Rating:
120 VAC
Compare With Similar Items
Kidde 21007583 Firex Wire-In Smoke Alarm With Battery Backup, 85 DB At 10 FT Loud, 60 HZ Operating Frequency, 120 VAC Operating, 80 MILAMP Operating, 40 - 100 DEG F Operating, Environmental Conditions: Up To 85 PCT Relative Humidity (RH), Ionization...

I4618-A

$15.23 /ea

Kidde 21007583 Firex Wire-In Smoke Alarm With Battery Backup, 85 DB At 10 FT Loud, 60 HZ Operating Frequency, 120 VAC Operating, 80 MILAMP Operating, 40 - 100 DEG F Operating, Environmental Conditions: Up To 85 PCT Relative Humidity (RH), Ionization Sensor, Dimensions: 5.6 IN Diameter X 1.8 IN Depth, LED Display, Mounting: Single Gang Electrical Box, Up To 4 IN Octagon Box, Included: 9 V Battery, Sensitivity: 0.5 - 0.92 PCT/FT, UL 217, NFPA 72, (Chapter 11) The State of California Fire Marshall, NFPA 101 (One And Two Family Dwellings), Federal Housing Authority (FHA), Housing And Urban Development (HUD)

Kidde 21006371 Firex Smoke Alarm With Battery Backup, 85 DB At 10 FT Loud, 60 HZ Operating Frequency, 120 VAC Operating, 80 MILAMP Operating, 40 - 100 DEG F Operating, Environmental Conditions: 5 - 95 PCT Relative Humidity (RH), Photoelectric Sensor,...

PE120E

$22.87 /ea

Kidde 21006371 Firex Smoke Alarm With Battery Backup, 85 DB At 10 FT Loud, 60 HZ Operating Frequency, 120 VAC Operating, 80 MILAMP Operating, 40 - 100 DEG F Operating, Environmental Conditions: 5 - 95 PCT Relative Humidity (RH), Photoelectric Sensor, Dimensions: 5.6 IN Diameter X 1.55 IN Depth, Flashing LED Display, Mounting: Single Gang Electrical Box, Up To 4 IN Octagon Box, Included: 9 V Battery, Sensitivity: 1.2 - 3.36 PCT/FT, UL 217, NFPA 72, (Chapter 11 2002 Edition) The State Of California Fire Marshall, NFPA 101 (One And Two Family Dwellings) Federal Housing Authority (FHA), Housing And Urban Development (HUD)

Power Source: 3 AA Batteries, Sensor:Electrochemical, Audio Alarm:85dB at 10ft, Temperature Range:40F (4.4C) to 100F (37.8C) Humidity Range:10 PCT -95 PCT relative humidity (RH), Size:3.0INx 5.0INx 1.5IN, Weight:.44lbs with battery

KN-COB-B-LS

$30.24 /ea

Power Source: 3 AA Batteries, Sensor:Electrochemical, Audio Alarm:85dB at 10ft, Temperature Range:40F (4.4C) to 100F (37.8C) Humidity Range:10 PCT -95 PCT relative humidity (RH), Size:3.0INx 5.0INx 1.5IN, Weight:.44lbs with battery

ADDED TO CART