Call Us Today: (800) 462-7733
NEW Wadsworth replacement circuit breaker type A by Connecticut Electric. For use in Wadsworth load centers that accept type A (1
NEW Wadsworth replacement circuit breaker type A by Connecticut Electric. For use in Wadsworth load centers that accept type A (1

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

UBIA50NI

$63.13 / EA

In stock (0)
Lead time: over 7 days
may be longer on small orders

NEW Wadsworth replacement circuit breaker type A by Connecticut Electric. For use in Wadsworth load centers that accept type A (1" wide) breakers. ETL Listed. 10,000 AIC. 1-pole, 50A

NEW Wadsworth replacement circuit breaker type A by Connecticut Electric. For use in Wadsworth load centers that accept type A (1" wide) breakers. ETL Listed. 10,000 AIC. 1-pole, 50A

150

UPC
094925008142
UNSPSC
39121601
Country of Origin
CHN
Amperage Rating:
50 A
Material:
DMC
Number Of Poles:
1
Type:
UBIA TYPE A THICK REPLACEMENT
Voltage Rating:
120 VAC
Actuator:
Handle
Amperage Rating:
50 A
Connection:
Push On
Enclosure:
Appropriate OEM Panelboard i.e. Wadsworth
Environmental Conditions:
Determined by panel for product
Frequency Rating:
50/60 Hz
Height:
2.73 in
Interrupt Rating:
10000 AIC
Length:
3.76 IN
Load Rating:
1
Material:
DMC
Number Of Poles:
1
Operating Temperature:
40 Celsius
Phase:
1
Standard:
ETL Listed
Sub Brand:
UBIA
Trip Type:
Thermal
Type:
UBIA TYPE A THICK REPLACEMENT
Voltage Rating:
120 VAC
Width:
1 in
Compare With Similar Items
Zinsco circuit breaker by Connecticut Electric Type UBIZ. For use in Zinsco load centers that accept type RC circuit breakers. ETL Listed. 10,000 AIC 2-pole 15A

UBIZ0215

$86.11 /ea

Zinsco circuit breaker by Connecticut Electric Type UBIZ. For use in Zinsco load centers that accept type RC circuit breakers. ETL Listed. 10,000 AIC 2-pole 15A

Attributed Data Included
Actuator Handle Yes
Connection Push On Yes
Enclosure Appropriate OEM Panelboard i.e. Zinsco Yes
Environmental Conditions Determined by panel for product Yes
Load Rating 1 Yes
Material DMC Yes
Number Of Poles 2 Yes
Phase 1 Yes
Standard ETL Listed Yes
Sub Brand UBIZ Yes
Trip Range None Yes
Trip Type Thermal Yes
Type UBIZ TYPE RC THIN REPLACEMENT Yes
Zinsco circuit breaker by Connecticut Electric Type UBIZ. For use in Zinsco load centers that accept type RC circuit breakers. ETL Listed. 10,000 AIC 2-pole 20A

UBIZ0220

$84.41 /ea

Zinsco circuit breaker by Connecticut Electric Type UBIZ. For use in Zinsco load centers that accept type RC circuit breakers. ETL Listed. 10,000 AIC 2-pole 20A

Attributed Data Included
Actuator Handle Yes
Connection Push On Yes
Enclosure Appropriate OEM Panelboard i.e. Zinsco Yes
Environmental Conditions Determined by panel for product Yes
Load Rating 1 Yes
Material DMC Yes
Number Of Poles 2 Yes
Phase 1 Yes
Standard ETL Listed Yes
Sub Brand UBIZ Yes
Trip Range None Yes
Trip Type Thermal Yes
Type UBIZ TYPE RC THIN REPLACEMENT Yes
Zinsco circuit breaker by Connecticut Electric Type UBIZ. For use in Zinsco load centers that accept type RC circuit breakers. ETL Listed. 10,000 AIC 2-pole 25A

UBIZ0225

$84.41 /ea

Zinsco circuit breaker by Connecticut Electric Type UBIZ. For use in Zinsco load centers that accept type RC circuit breakers. ETL Listed. 10,000 AIC 2-pole 25A

Attributed Data Included
Actuator Handle Yes
Connection Push On Yes
Enclosure Appropriate OEM Panelboard i.e. Zinsco Yes
Environmental Conditions Determined by panel for product Yes
Load Rating 1 Yes
Material DMC Yes
Number Of Poles 2 Yes
Phase 1 Yes
Standard ETL Listed Yes
Sub Brand UBIZ Yes
Trip Range None Yes
Trip Type Thermal Yes
Type UBIZ TYPE RC THIN REPLACEMENT Yes

ADDED TO CART